Difference Between Synchronous and Asynchronous Counter
Basis for Comparison | Synchronous Counter | Asynchronous Counter |
---|---|---|
Also called | Parallel Counter | Serial Counter |
Principle of operation | Each flip flop is triggered with same clock signal at the same time. | Each flip flop is triggered with different clock signal at different instant of time. |
Decoding errors | Not produced | Produced |
Operating speed | Fast | Comparatively slow |
Design | Complex | Simple |
Delay in signal propagation | Very Low | Comparatively high |
Count sequence | Not Fixed | Fixed |
Response to clock signal | Each flip-flop changes its state simultaneously. | There is no simultaneous change in the state of all flip flops with change in clock input. |
Overall settling time | Maximum settling time out of the settling time of each flip flop in the configuration. | Summation of settling time of each individual flip-flop. |
Flip-flop direct interconnection | Not Exist | Exist |
Applications | In moving machine controlling, alarms clocks, multiplexing circuits, etc. | In ring and johnson counters, frequency dividers, etc. |
Advantages and Disadvantages of Outdoor Substation
Advantages of Outdoor Substation
The outdoor substations have the following main advantages. These are
All the equipment in the outdoor substations is within view, and therefore fault location is easier.
The expansion of the installation is easier in the outdoor substations.
The time requires in the construction of such substations is lesser.
The smaller amount of building material like steel, concrete is required.
The construction work required is comparatively less, and the cost of the switchgear installation is also very low.
Repairing work is easy, and proper space is provided between the apparatus so that the fault occur at one point will not be carried over to another point.
Disadvantages of Outdoor Substation
More space is required for the outdoor substations.
Protection devices are required to be installed for the protection against lightning surges.
The length of the control cables increases which increase the cost of the substation.
Equipment designed for outdoor substation are more costly because outdoor door substation equipment required additional protection from the dirt and dust.
In spite of the disadvantage, outdoor substations are very widely used in the power system.
Transformer Fittings And Accessories
Oil conservator with drain plug and oil filling hole Oil level indicator Drain valve with plug Filter valve with plug Air release vent Exp...
-
A Static Transfer Switch (STS) utilizes a static electronic component (SCR), which permits a transfer in less than four milliseconds (1/4 o...
-
Electrical secondary equipment generally refers to the various types of microcomputer protection and control device, microcomputer seconda...
-
Elements - RESISTOR - CAPACITANCE OR CAPACITOR - INDUCTOR = reactance = impedance =susceptance =admittance - VOLTAGE SOURCE - CURRENT...
-
The auxiliary class protection device refers to some unusual protection devices with auxiliary function,the main products are 961 communic...
-
. Earthing system or grounding system connects specific parts of that installation with the Earth's conductive surface for safety and ...
-
Main transformer protection Line Protection Transformer protection Motor protection Capacitor protection Generator protection auto-put-into ...
-
generator backup protection relay is applicable to the generator protection that the water turbine capacity whose power is not more than 1...
-
Line protection measurement and control device is simply illustrated that is the device used for the line cabinets and outlet cabinets for p...
-
busbar differential protection relay is suitable for the 110KV and the following various voltage levels of a single bus、Single parent segm...