POWER
Electric power definition
The electric power P is equal to the energy consumption E divided by the consumption time t:
P is the electric power in watt (W).
E is the energy consumption in joule (J).
t is the time in seconds (s).
Example
Find the electric power of an electrical circuit that consumes 120 joules for 20 seconds.
Solution:
E = 120J
t = 20s
P = E / t = 120J / 20s = 6W
Electric power calculation
P = V ⋅ I
or
P = I 2 ⋅ R
or
P = V 2 / R
P is the electric power in watt (W).
V is the voltage in volts (V).
I is the current in amps (A).
R is the resistance in ohms (Ω).
Power of AC circuits
The formulas are for single-phase AC power.
For 3 phase AC power:
When line to line voltage (VL-L) is used in the formula, multiply the single phase power by square root of 3 (√3=1.73).
When the line to zero voltage (VL-0) is used in the formula, multiply the single-phase power by 3.
Real power
Real or true power is the power that is used to do the work on the load.
P = Vrms Irms cos φ
P is the real power in watts [W]
Vrms is the rms voltage = Vpeak/√2 in Volts [V]
Irms is the rms current = Ipeak/√2 in Amperes [A]
φ is the impedance phase angle = phase difference between voltage and current.
Reactive power
Reactive power is the power that is wasted and not used to do work on the load.
Q = Vrms Irms sin φ
Q is the reactive power in volt-ampere-reactive [VAR]
Vrms is the rms voltage = Vpeak/√2 in Volts [V]
Irms is the rms current = Ipeak/√2 in Amperes [A]
φ is the impedance phase angle = phase difference between voltage and current.
Apparent power
The apparent power is the power that is supplied to the circuit.
S = Vrms Irms
S is the apparent power in Volt-amper [VA]
Vrms is the rms voltage = Vpeak/√2 in Volts [V]
Irms is the rms current = Ipeak/√2 in Amperes [A]
Real / reactive / apparent powers relation
The real power P and reactive power Q give together the apparent power S:
P2 + Q2 = S2
P is the real power in watts [W]
Q is the reactive power in volt-ampere-reactive [VAR]
S is the apparent power in Volt-amper [VA]
Transformer Fittings And Accessories
Oil conservator with drain plug and oil filling hole Oil level indicator Drain valve with plug Filter valve with plug Air release vent Exp...
-
A Static Transfer Switch (STS) utilizes a static electronic component (SCR), which permits a transfer in less than four milliseconds (1/4 o...
-
Electrical secondary equipment generally refers to the various types of microcomputer protection and control device, microcomputer seconda...
-
Elements - RESISTOR - CAPACITANCE OR CAPACITOR - INDUCTOR = reactance = impedance =susceptance =admittance - VOLTAGE SOURCE - CURRENT...
-
The auxiliary class protection device refers to some unusual protection devices with auxiliary function,the main products are 961 communic...
-
. Earthing system or grounding system connects specific parts of that installation with the Earth's conductive surface for safety and ...
-
Main transformer protection Line Protection Transformer protection Motor protection Capacitor protection Generator protection auto-put-into ...
-
generator backup protection relay is applicable to the generator protection that the water turbine capacity whose power is not more than 1...
-
Line protection measurement and control device is simply illustrated that is the device used for the line cabinets and outlet cabinets for p...
-
busbar differential protection relay is suitable for the 110KV and the following various voltage levels of a single bus、Single parent segm...