ELCB is used to detect earth leakage fault. Once the phase and neutral are connected in an ELCB, the current will flow through a phase and that much current will have to return neutral so the resultant current is zero. Once there is a ground fault in the load side, current from phase will directly pass through earth and it will not return through neutral through ELCB. That means once side current is going and not returning and hence because of this difference in current ELCB will trip and it will safeguard the other circuits from faulty loads. If the neutral is not grounded, fault current will definitely high and that full fault current will come back through ELCB, and there will be no difference in current.
Translate
THANKS
Thanks for being touch with us on Social media and online website
×
Thanks! for visiting the electricaldon.com website.Received many applications for ITI ELECTRICIAN for job.
Kindly note our team is working on it, shortly you will receive call from them.
!doctype>
APPLY only if you have Electrical wiremen or Electrical Supervisor Licenses its Mandatory. !
Thankyou for your Patients. !
Search This Blog
category
- Electrical (190)
- Q & A (81)
- Difference Between (26)
- Types of (18)
- CALCULATOR (16)
- BOOKS (8)
- Calculate (3)
- Tests (2)
- Advantage & Disadvantage (1)
- Formulas (1)
- SAFETY (1)
- Shortcuts (1)
Subscribe to:
Post Comments (Atom)
Transformer Fittings And Accessories
Oil conservator with drain plug and oil filling hole Oil level indicator Drain valve with plug Filter valve with plug Air release vent Exp...
-
A Static Transfer Switch (STS) utilizes a static electronic component (SCR), which permits a transfer in less than four milliseconds (1/4 o...
-
Electrical secondary equipment generally refers to the various types of microcomputer protection and control device, microcomputer seconda...
-
WTI and OTI of Transformer The WTI means winding temperature Indicator and OTI means Oil Temperature Indicator which indicates the win...
-
Elements - RESISTOR - CAPACITANCE OR CAPACITOR - INDUCTOR = reactance = impedance =susceptance =admittance - VOLTAGE SOURCE - CURRENT...
-
The auxiliary class protection device refers to some unusual protection devices with auxiliary function,the main products are 961 communic...
-
. Earthing system or grounding system connects specific parts of that installation with the Earth's conductive surface for safety and ...
-
Main transformer protection Line Protection Transformer protection Motor protection Capacitor protection Generator protection auto-put-into ...
-
generator backup protection relay is applicable to the generator protection that the water turbine capacity whose power is not more than 1...
-
busbar differential protection relay is suitable for the 110KV and the following various voltage levels of a single bus、Single parent segm...
No comments:
Post a Comment