Its ratio between insulation resistance (IR) i.e. megger value for 10min to insulation resistance for 1 min. It ranges from 5-7 for new motors & normally for the motor to be in good condition it should be Greater than 2.5. Polarization Index Test (PI) – The PI test measures the ability of the insulation to absorb voltage over a period of time. This gives an indication of the overall insulation quality of the individual pieces of insulation in the transformer. This test is usually performed in conjunction with the Megger Test. It is measured as the ratio of insulation resistance (IR) for 10 minutes to insulation resistance for 1 minute.
Translate
THANKS
Thanks for being touch with us on Social media and online website
×
Thanks! for visiting the electricaldon.com website.Received many applications for ITI ELECTRICIAN for job.
Kindly note our team is working on it, shortly you will receive call from them.
!doctype>
APPLY only if you have Electrical wiremen or Electrical Supervisor Licenses its Mandatory. !
Thankyou for your Patients. !
Search This Blog
category
- Electrical (190)
- Q & A (81)
- Difference Between (26)
- Types of (18)
- CALCULATOR (16)
- BOOKS (8)
- Calculate (3)
- Tests (2)
- Advantage & Disadvantage (1)
- Formulas (1)
- SAFETY (1)
- Shortcuts (1)
Subscribe to:
Post Comments (Atom)
Transformer Fittings And Accessories
Oil conservator with drain plug and oil filling hole Oil level indicator Drain valve with plug Filter valve with plug Air release vent Exp...
-
A Static Transfer Switch (STS) utilizes a static electronic component (SCR), which permits a transfer in less than four milliseconds (1/4 o...
-
WTI and OTI of Transformer The WTI means winding temperature Indicator and OTI means Oil Temperature Indicator which indicates the win...
-
IP Code, or Ingress Protection Code[1], IEC standard 60529, sometimes interpreted as International Protection Code, classifies and rates th...
-
Open circuit test or No-load Test of Transformer The Open circuit test of the transformer is one of the type test of transformer by which ...
-
Low voltage measurement and control device is mainly used for the measurement and control of 0.4KV voltage grade of low voltage wire feedi...
-
Elements - RESISTOR - CAPACITANCE OR CAPACITOR - INDUCTOR = reactance = impedance =susceptance =admittance - VOLTAGE SOURCE - CURRENT...
-
Earthing or Neutral Grounding Transformer When a transformer is used for the purpose of providing a neutral point for grounding purpose in...
-
auto-put-into device of reserve-source device is divided into the incoming line and the busbar connection,The device can be used in the 11...
-
Electrical secondary equipment generally refers to the various types of microcomputer protection and control device, microcomputer seconda...
No comments:
Post a Comment